Sammode
  • Products
    • Industrial Luminaires
      • General lighting
      • Lighting for hazardous areas (ATEX)
      • Lighting for extreme-heat environments
      • High-bay lighting
      • Emergency lighting
      • Clean room lighting
      • Lighting for extreme cold
      • Cable entries
      • LED conversion kits
    • Architectural Luminaires
      • Wall lamp
      • Ceiling & suspension
      • Outdoor lighting
      • Chandelier
      • Emergency lighting
      • LED conversion kits
      • Our lighting collections
    • Design Luminaires
      • Wall lamp
      • Ceiling & suspension
      • Table lamp
      • Floor lamp
      • Our lighting collections
    • Luminaires comparator
    • Smart Lighting
    •  
    •  
    •  
  • Applications
    • Industry & Agri-food
      • Industry Industry
        • Industrial building lighting – Metallurgy & Iron & Steel
        • Paper industry
        • Hazardous area lighting (IECEx & ATEX)
      • Food & Beverage Food & Beverage
        • Sugar refineries
        • Cheese and dairy industry
        • Malting plants and distilleries
      • Utilities / Energy Utilities / Energy
        • Nuclear
        • Water treatment
    • Infrastructure & Transport
      • Operating areas Operating areas
        • Port infrastructures
        • Bus station and depot lighting
        • Railway tunnel lighting
        • Railways
      • Reception areas Reception areas
        • Transport & Mobility
        • Car parks
    • Architecture & Design
      • Sites Sites
        • Administrative and public buildings
        • Hotels and restaurants
        • Offices
        • Residential dwellings
        • Outdoor areas
        • Education
        • Retail lighting
      • Technologies, variants Technologies, variants
        • LED conversion kits
        • Pierre Guariche x Michel Mortier reissue
        • Sammode designer chandelier
  • Projects
  • About us
    • About us
      • History
      • CSR
      • Our values
      • Research & Development
    • Our Showrooms
      • Industry Showroom
      • Showroom Architecture
  • Downloads
    • Industry & Infrastructure
    • Architecture & Hospitality
    • Studio collection
  • News
    • Latest news
    • Newsletter subscription
    • Follow us
E-shop
  • EN
    • FR
    • DE
  • Contact
  • Press
  • Media library
  • Technical support
  • EN
    • FR
    • DE
  • Contact
  • Press
  • Media library
  • Technical support

Knowledge base

7
  • Lighting management
  • The strength of the Sammode tubular system
  • Color rendering index (CRI)
  • Color temperature
  • Directional and diffuse optics: find the perfect light for every space
  • DALI dimming: control your lighting with precision and flexibility
  • Discomfort glare or UGR

Maintenance guides

2
  • Cleaning the stainless steel parts of a luminaire: what are the best practices?
  • How do I care for brass light fittings from the Guariche collection?

Guides for switching to LED

1
  • LED Stage mounting tutorial ⌀70 mm
  • Home
  • Guides
  • Maintenance guides
  • Cleaning the stainless steel parts of a luminaire: what are the best practices?
View Categories

Cleaning the stainless steel parts of a luminaire: what are the best practices?

Stainless steel is easier to clean and more suitable for disinfection than aluminium or polymers, thanks to its special surface properties. Cleaning stainless steel involves removing visible and non-visible dirt that adheres to the surface, rather than destroying micro-organisms.

However, improper use of cleaning products can lead to corrosion, particularly if the product is overdosed, not rinsed thoroughly enough or at too high a temperature.

Recommendations for maintaining the stainless steel parts of your luminaire #

Glass degreasers, non-bleach detergents (washing powders, liquid detergents and soaps) and washing soda are harmless to stainless steel.

It is preferable to use commercial cleaning products (and not the active ingredients alone) as they generally contain corrosion inhibitors. Be sure to observe their optimum conditions of use.

To disinfect stainless steel, it is generally sufficient to use products with a concentration 10 to 100 times lower than for other materials.

How often should you clean the stainless steel parts of your luminaire? #


As a guide, here’s how often you should clean your luminaire’s stainless steel. This frequency should be adapted to the actual conditions of installation and use.

Type of atmosphere
Type of stainless steelRuralUrbanIndustrialAggressive industrialMarineSeafrontMarine
Stainless steel (standard) – 304L>6 months3~6 months3~6 months1~3 months1~3 months<1 months
Marine stainless steel – 316L>6 months>6 months(>6 months)3~6 months3~6 months1~3 months
Approximate cleaning frequency

Operating procedure and tools #

Cleaning in the same direction as polishing. In any case, always in the same direction. Use high-pressure cleaners, with or without detergents, and/or hot water. Generally speaking, use clean tools.

Note: before taking any action, make sure that the method of cleaning envisaged, in particular the use of a high-pressure cleaner or low-pressure liquid, is compatible with the IP protection rating of the luminaire (sufficient tightness).

Rinsing and drying #

Rinse with plenty of water: after using any cleaning product on the stainless steel parts of the luminaire, always rinse with fresh water. Wipe with a rubber squeegee or, failing that, a clean soft cloth.

Precautionary measures #

Quelques précautions à suivre.

Tools #

  • Do not use metal brushes, pads or wool, hard brushes or nylon brushes
  • Do not use abrasive pads or powders (even very fine ones)

Products #

  • Do not use chlorine or bleach products: Bleach and chlorine derivatives can only be used very diluted and for limited contact times.
  • Do not use hydrochloric acid, or any product with an unknown or unsuitable composition: nitric, hydrofluoric, etc.
  • Do not use waxes designed to increase the shine of surfaces: they leave a film that can encourage particles to adhere to surfaces.
  • Before taking any action, make sure that the cleaning method envisaged, in particular the use of a high-pressure cleaner or low-pressure liquid, is compatible with the IP protection rating of the luminaire (sufficient tightness).

Remarks #

  • The use of acidic products or solvents requires special precautions, both for the user and for the surrounding materials. This operation should always be followed by a thorough rinse with water.
  • We cannot be held responsible for any damage resulting from a change in the composition of the product or from misuse.
  • It is the user’s responsibility to check with the manufacturer that the product is suitable for use.
  • Traces of oxidation do not affect the operation of the product and are not covered by the warranty.
Still stuck? How can we help?

How can we help?

Updated on 11 June 2025
How do I care for brass light fittings from the Guariche collection?
Table des matières
  • Recommendations for maintaining the stainless steel parts of your luminaire
  • How often should you clean the stainless steel parts of your luminaire?
  • Operating procedure and tools
  • Rinsing and drying
  • Precautionary measures
    • Tools
    • Products
    • Remarks
Sammode

24 rue des Amandiers
75020 Paris, France

[email protected]

+33 (0)1 43 14 84 90

Applications

Industry & Agri-foodIndustryInfrastructure & TransportArchitecture & DesignAgri-foodUtilities / EnergyDesignersOperating AreasReception AreasSitesTechnologies, Variants

About us

    Sammode, a century of historyResearch & DevelopmentCSRPartnersOur values
E-shopContactGTCWarranty

Keep up to date – Newsletter

* indicates required fields.

This field is for validation purposes and should be left unchanged.
d*
  • © 2025 Sammode  | 
  • Legal notice  | 
  • Privacy policy  | 
  • Credits  | 
Sammode respects your privacy

In order to provide you with the best possible experience, Sammode uses cookies to improve your browsing experience, personalise your content and analyse site performance.

Your choice will be retained for 6 months. You can change your mind at any time by clicking on the "Cookie policy" link at the bottom of the page.

Continue without acceptingConfigure cookiesAccept and close
Manage consent

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.