Language
  • Volta 133
  • Volta 1332
  • Volta 1333
<Volta 133

Volta 133Easy maintenance impervious tubular light fitting for replacement lighting

REPLACEMENT LIGHTING

NF 60598-2-22
Maintained and non-maintained
Automatic testing according to IEC 62034
LED indicator light

TUBULAR

Increased mechanical resistance
Easy to clean
Limited dirt accumulation
360° orientation

IMPERVIOUS (IP68/IP69K)

Absolute imperviousness
No internal dust accumulation
Maximum light output
Adapted for pressure cleaning

EASY MAINTENANCE

Easy opening and closing with just one screw
Relamping without need to remove the gear tray

DURABLE

High resistance to corrosion and external aggression
Robustness of the housing, quality of the materials and components: long-term investment

HOUSING

• Ø133 mm crystal quality polycarbonate Diffuser
• End caps 1/2 ring press-formed in 304L stainless steel (316L also available)
• Gaskets moulded in EPDM
• Cable entry with cable gland (disconnectable plug available)
• Possibility for a model with 2 cable entries for looping-in (2 entries on the same cap)

GEAR TRAY

• White powder coated steel sheet gear tray, indexed in rotation and lockable
• Emergency unit with automatic duration and function tests for self-contained luminaires
• Push-button to launch tests manually
• Battery lifetime 1h or 3h
• Internal wiring with silicon isolated wires braided with glass fibre

REFLECTOR

• White powder-coated gear tray serving as a reflector for general diffused lighting
• Extensive reflector in mirror finish aluminium, available on option

INSTALLATION – MAINTENANCE

• Connection to 4x2,5mm² detachable terminal block
• Installation with 2 bolt-fitted stainless steel straps with variable centre distance and allowing 360°orientation (available in a reinforced model and/or with closure using a HSHC screw)
• Maintenance by removing the end cap and sliding the guided gear plate (patented system)

ELECTRICAL CLASS

Class 1

LAMP TYPE

2 T5 or T8 fluorescent lamps (1 self-contained lamp)

EMEGENCY POWER FLUX (according to power)

1-hour emergency mode 450 to 725lm
3-hour emergency mode 100 to 250lm

FIRE RESISTANCE

960°C

PROTECTION

IP66, IP68 and IP69K

SHOCK RESISTANCE

IK10

OPERATING TEMPERATURE

0°C +30°C

Principal references

PowerDesignationDimensionsDownload
VERSIONS WITH 1 HOUR EMERGENCY BACK-UP - Electronic gear unit for T8 lamps
450lmVOL133 S1H 236E G13 PO 1161355mmTechnical Data [zip]
525lmVOL133 S1H 258E G13 PO 1161655mmTechnical Data [zip]
VERSIONS WITH 1 HOUR EMERGENCY BACK-UP - Electronic gear unit for T5 lamps
725lmVOL133 S1H 235E G5 PO 1161595mmTechnical Data [zip]
600lmVOL133 S1H 254E G5 PO 1161295mmTechnical Data [zip]
VERSIONS WITH 3 HOURS EMERGENCY BACK-UP - Electronic gear unit for T8 lamps
200lmVOL133 S3H 236E G13 PO 1161355mmTechnical Data [zip]
175lmVOL133 S3H 258E G13 PO 1161655mmTechnical Data [zip]
VERSIONS WITH 3 HOURS EMERGENCY BACK-UP - Electronic gear unit for T5 lamps
250lmVOL133 S3H 235E G5 PO 1161595mmTechnical Data [zip]
100lmVOL133 S3H 254E G5 PO 1161295mmTechnical Data [zip]