<Niepce 70 T5

Niepce 70 T5Small impervious tubular light fitting

TUBULAR

Increased mechanical resistance
Easy to clean
Limited dirt accumulation
360° orientation

IMPERVIOUS (IP68/IP69K)

Absolute imperviousness
No internal dust accumulation
Maximum light output
Adapted for pressure cleaning


EASY INSTALLATION AND MAINTENANCE

Patented system with automatic connection on closure (Close'n Connect)
Maintenance without tampering with the cable by removal of the endcap without cable entry

SMALL LIGHT FITTING

70 mm diameter
The positioning of the gear unit to the rear of the gear tray on the T5 model enables reduced size and lighting over the entire length of the fitting.

DURABLE

High resistance to corrosion and external aggression
Robustness of the housing, quality of the materials and components: long-term investment


HOUSING

• Ø70 mm crystal quality polycarbonate diffuser
• Also available in coextruded polycarbonate/PMMA for outdoor lighting and agri-food environments
• End caps 1/2 ring press-formed in 304L stainless steel (316L also available)
• Gaskets moulded in EPDM
• Cable entry with nickel-coated brass cable gland for cable Ø of 8 - 12 mm
 

GEAR TRAY

• White powder coated steel sheet gear tray with patented system for automatic connection on closing (Close'n Connect)
• Hot cathode electronic gear unit (EEI A2)
• Dimmable version (EEI A1)
• Internal wiring with silicon isolated wires braided with glass fibre
 

REFLECTORS

• Range of technical reflectors in mirror finish aluminium sheeting intensive (narrow beam), extensive (wide beam)
 

INSTALLATION – MAINTENANCE

• Connection to 2.5 mm2 detachable terminal block
• Fixing with 2 bolt-fitted stainless steel straps with variable centre distance and allowing 360° orientation (available in a reinforced version and/or with closure using a HSHC screw)
• Maintenance without tampering with the cable by removal of the endcap without cable entry
 

ELECTRICAL CLASS

Class 1

LAMP TYPE

1 T5 fluorescent lamp

FIRE RESISTANCE

Polycarbonate 960°C
Coex. polycarbonate/PMMA 650°C

PROTECTION

IP68/IP69K

SHOCK RESISTANCE

IK10

OPERATING TEMPERATURE

-20°C +30°C

ENEC

5 year warranty

Principal references

PowerDesignationDimensionsDownload
Class 1 versions Gear unit for T5 standard lamps - intensive reflector
1x14W NIE70 114E G5 PO 113 RI 695 mmTechnical Data [zip]
1x21W NIE70 121E G5 PO 113 RI 995 mmTechnical Data [zip]
1x28W NIE70 128E G5 PO 113 RI 1295 mmTechnical Data [zip]
1x35W NIE70 135E G5 PO 113 RI 1595 mmTechnical Data [zip]
Class 1 versions Gear unit for T5 high output lamps - intensive reflector
1x24W NIE70 124E G5 PO 113 RI 695 mmTechnical Data [zip]
1x39W NIE70 139E G5 PO 113 RI 995 mmTechnical Data [zip]
1x54W NIE70 154E G5 PO 113 RI 1295 mmTechnical Data [zip]
1x80W NIE70 180E G5 PO 113 RI 1595 mmTechnical Data [zip]
1x49W NIE70 149E G5 PO 113 RI 1595 mm Technical Data [zip]
Class 1 versions Gear unit for T5 standard lamps - extensive reflector
1x14W NIE70 114E G5 PO 113 RE 695 mm Technical Data [zip]
1x21W NIE70 121E G5 PO 113 RE 995 mm Technical Data [zip]
1x28W NIE70 128E G5 PO 113 RE 1295 mm Technical Data [zip]
1x35W NIE70 135E G5 PO 113 RE 1595 mm Technical Data [zip]
Class 1 versions Gear unit for T5 high output lamps - extensive reflector
1x24W NIE70 124E G5 PO 113 RE 695 mm Technical Data [zip]
1x39W NIE70 139E G5 PO 113 RE 995 mm Technical Data [zip]
1x54W NIE70 154E G5 PO 113 RE 1295 mm Technical Data [zip]
1x80W NIE70 180E G5 PO 113 RE 1595 mm Technical Data [zip]
1x49W NIE70 149E G5 PO 113 RE 1595 mm Technical Data [zip]
Class 2 versions Gear unit for T5 high efficiency lamps - intensive reflector
1x14WNIE70 CL2 114E G5 PO 113 RI695Technical Data [zip]
1x21WNIE70 CL2 121E G5 PO 113 RI995Technical Data [zip]
1x28WNIE70 CL2 128E G5 PO 113 RI1295Technical Data [zip]
1x35WNIE70 CL2 135E G5 PO 113 RI1595Technical Data [zip]
Class 2 versions Gear unit for T5 standard lamps - extensive reflector
1x14WNIE70 CL2 114E G5 PO 113 RE695Technical Data [zip]
1x21WNIE70 CL2 121E G5 PO 113 RE995Technical Data [zip]
1x28WNIE70 CL2 128E G5 PO 113 RE1295Technical Data [zip]
1x35WNIE70 CL2 135E G5 PO 113 RE1595Technical Data [zip]
Class 2 versions Gear unit for T5 high output lamps - intensive reflector
1x24WNIE70 CL2 124E G5 PO 113 RI695Technical Data [zip]
1x39WNIE70 CL2 139E G5 PO 113 RI995Technical Data [zip]
1x54WNIE70 CL2 154E G5 PO 113 RI1295Technical Data [zip]
1x80WNIE70 CL2 180E G5 PO 113 RI1595Technical Data [zip]
1x49WNIE70 CL2 149E G5 PO 113 RI1595Technical Data [zip]
Class 2 versions Gear unit for high output T5 lamps - extensive reflector
1x24WNIE70 CL2 124E G5 PO 113 RE695Technical Data [zip]
1x39WNIE70 CL2 139E G5 PO 113 RE995Technical Data [zip]
1x54WNIE70 CL2 154E G5 PO 113 RE1295Technical Data [zip]
1x80WNIE70 CL2 180E G5 PO 113 RE1595Technical Data [zip]
1x49WNIE70 CL2 149E G5 PO 113 RI1595Technical Data [zip]