Technical data 

Light source 

• High-efficiency removable LED modules (165lm/W, IRC>80, 3 SDCM)
• 50 000 h L80/B10 at max. operating temperature

Optics 

• Special satin-finish housing for LED
• Light mixing chamber

Light comfort 

Brightness management using a satin-finish housing

Photobiological hazard 

Group 0

Heat management

Passive heat sink in aluminium

Control gear 

Constant current driver (non-dimmable)

Rapid installation 

Connection 

• With nickel-coated brass cable gland for cable Ø 5 - 12 mm
• To a 3x2.5 mm² disconnectable terminal block
• Installation in vertical position: cable gland positioned downwards

Closing 

Closing by tightening the nut on the cable gland

Fixing 

2 stainless steel fixing straps (with variable centre distance)

Easy maintenance 

LED engine maintenance 

• Quick opening and closing with just one screw
• Maintenance without tampering with the cable by removal of the end cap without cable entry
• Patented system with automatic electrical connection/disconnection on closure
• Easily removable LED modules and driver

Materials and finishing 

Housing 

Special satin-finish polycarbonate housing for LEDs

End caps, fixing straps … 

304L stainless steel

Gaskets 

Moulded EPDM gaskets

Technical data 

Power supply 

220-240 V 50/60 Hz

Electrical class

Class I

Operating temperature 

-5 °C to +35 °C

Imperviousness 

IP66, IP68 and IP69K

Shock resistance 

IK10

Principal references

PowerDesignationDimensionsDownload
1500 lm METSYS 1500-827995 mmTechnical Data [zip]
2000 lm METSYS 2000-8271275 mmTechnical Data [zip]
1500 lmMETSYS 1500-830995 mmTechnical Data [zip]
2000 lm METSYS 2000-8301275 mmTechnical Data [zip]
1500 lmMETSYS 1500-840995 mmTechnical Data [zip]
2000 lm METSYS 2000-840METSYS 2000-840Technical Data [zip]